P1: Nitrous at Balls in '09TestingFifth Hot Fire TestLast Update, 1/1/09 by Stephen Daniel |
ContentsSummary of ResultsBoth burns were successful. Two nearly identical burns. Good data from one. C* efficiency estimates are still being worked on, but look to be in the ~70% range. Video from test 11 is up on YouTube. Pressure data and simulation results are here. Test PlanGoals for this test:
Based on analysis of our last test, we've made these decisions.
ScheduleTest day is December 29 at Rik's. Evan and I plan to arrive by 11:00 AM. Spectators are welcome at 11:00, and should definitely arrive before noon. First hot-fire test: push the button some time between 12:00 and 12:30. Lunch between tests. Second hot-fire test: push the button no later than 3:00. Goal is 1:30. Depart: goal is 4:00. Pretest WorkPyro-valvesMark-4 pyro-valves. Ready. HydrotestingHydrotesting did not go well. We managed to get a fair amount of air into the system which in turn meant we spent a lot of time and effort for little result. Valve #2 was measured to hold at 600 psi before the system leaked down to 400 psi. The leak was at the injector end, and our belief is that the leak was fluid passing the main injector bulkhead rings. Our assumption is that the rings are loose and that our silicon hydraulic fluid managed to get past the grease. We pulled the injector, cleaned and inspected the rings, cleaned the motor, and reassembled. We did not repeat the hydrotest. (Note: injector bulkhead rings are viton.) Fuel GrainsWe will use 12" ABS grains that were prepared for the last test. Nitrous SupplyI exchanged our 50 lb nitrous cylinder (mostly empty) for a 75 lb nitrous cylinder. We'll be using Mike's 15 lb cylinder for testing. We need to refill Mike's cylinder before testing. Weights and Measures
First test will be grain #2, valve #2. Nitrous Supply
Data CaptureDAQ firmware needs some slight tweaks, but is basically ready to run. We will continue to use our temporary mounting for this test. ResultsTest 10
Test 11
Final weight of the nitrous supply tank was 24.6 lbm, indicating we consumed 8.4 lbm of nitrous during these two tests.
|